Pc1832 programming manual

Doing so may cause problems in the function of your alarm system. Even though your system comes factory defaulted; we suggest that you default the system just to make sure you pc1832 programming manual a clean slate to work with. To do this; follow the steps below:. To default the system you will enter into programming mode by typing:.

Forever nerd and SaaS entrepreneur. Intrigued by software engineering, software as a business and aviation. I purchased the IT board and then decided I wanted to expand it a bit further to include more zones. I quickly realized I could use the IT board and some time to systematically determine the installer code but the time spent on that would be spent only because I had some concerns regarding reprogramming it. I decided to reprogram it myself and here are my notes for anyone attempting to program or even reprogram their own DSC alarm. The process is incredibly straight forward with only a few caveats.

Pc1832 programming manual

.

Here is how I programmed it and the order I went through: Enroll the keypads Switch to normally-closed loops non-resistive circuits Program the zones Cancel the telephone system as it is monitored via the Internet Set the partitioning for expanded zones Check the pc1832 programming manual Reset the master code Reset the installer code victory Items of Note I programmed my system in a single partition partition 1 My alarm is monitored via the Internet and not via the telephone system s built into the DSC Enroll the Keypads I have four keypads plus the IT so my keypad bus is busy. Enter Section and enter 11 sixteen times 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 and then the system will beep 3 times, pc1832 programming manual, pc1832 programming manual.

.

Table Of Contents. Table of Contents. Quick Links. This manual contains information on limitations regarding product use and function and information on the limitations as to liability. The entire manual should be carefully read. Previous Page. Next Page. Page 7: Additional Devices PC v1.

Pc1832 programming manual

.

Calendario editable 2023 excel

You have to tell the DSC this or it will think all of the zones are in an alarm state. You cannot place any wireless device on a zone set that is shared with any hardwired zone. At each keypad I enrolled each one one by one. Thus, you have to ground Z1 to PGM and power the system up for 10 seconds and then power it off, remove the jumper and then power it back on. We want our Sample Alarm for demonstration purposes to have 30 second delays for entry and exit. This code is what you use to arm and disarm the system with. After entering the Installer Code we will now be in the Programming Section. Below are additional sections you need to go into: Press to change your installer code from the default setting of Version 4. Note: if you see other toggle options on, just ignore the other options and only worry about what is being said on this guide. Programming Section will allow us to change the delay times. Options that are off will not be visible.

.

After each two-digit definition, the system will beep and automatically want the definition for the next zone. This code is what you use to arm and disarm the system with. Here was my table of zones and types:. If you are using 17 or more, but less than 24 zones, use programming section add 16 to each numbered zone to get that zone. Step 2 Adding Zone Definitions Program Section We will begin adding our Zone Definitions and will use the above chart for reference and we will go straight down the list which begins with Zone Number Enter each number as. If at anytime you get lost, STOP, and hit , and then start over. If you have only four 4 hardwired zones, you would use zones and then you can begin your wireless on zone 9 which is on a different set of 8 zones. Here is a list of the most common Zone Definitions:. After entering the zone number, you will need to enter the ESN number. You will enter into programming by pressing. To default the system you will enter into programming mode by typing:. To enroll a wireless device, you must open, close, or tamper the device while the keypad says wireless enrollment mode. This means we will enter into Programming Section and turn off zones 5, 6, 7, and 8. A: You do not the DSC alarm can be programmed to work with normally closed loops as long as it is not a UL requirement.

1 thoughts on “Pc1832 programming manual

Leave a Reply

Your email address will not be published. Required fields are marked *