airwell air conditioner troubleshooting

Airwell air conditioner troubleshooting

Contact your installer or your nearest Airwell dealer. Our Airwell authorised distributors and technical departments are continuously trained to provide you with a professional and efficient service.

Products of the French company Airwell is known for decades. The company Airwell was founded in the and today it is one of the largest producer of HVAC equipment in the world. Airwell produces all types of home, semi-industrial and industrial air conditioning systems and markets more than models. Find below the Airwell air conditioner troubleshooting table, which will help in case of Airwell equipment failure. No power supply Check power supply.

Airwell air conditioner troubleshooting

If the malfunction still exists 4 minutes after the device stops due to compressor protection, the error code will be directly displayed on the display of the indoor unit. Possible reasons. RUN indicator off for 3s and blinks 2 times. Inner spiral defrost protection. RUN indicator off for 3s and blinks 4 times. Compressor overheat protection. RUN indicator off for 3s and blinks 5 times. Overvoltage Protection. RUN indicator off for 3s and blinks 6 times. Communication failure.

Replace the outdoor unit board. Shut them to keep the heat or cold out.

When the voltage supply is too high or too low the unit protection is activated and stop the system until the voltage become to normal value. And part of its protection mode. During deicing the unit will defrost accumulated ice layer on the outdoor unit. Due to this procedure ice is melt and some of water drops may turn to steam, this process should take no more then min. And can be repeated from time to time.

Hide thumbs. Table of Contents. Quick Links. These air conditioners employ new. Pay special attention when. Previous Page. Next Page.

Airwell air conditioner troubleshooting

Products of the French company Airwell is known for decades. The company Airwell was founded in the and today it is one of the largest producer of HVAC equipment in the world. Airwell produces all types of home, semi-industrial and industrial air conditioning systems and markets more than models. Find below the Airwell air conditioner troubleshooting table, which will help in case of Airwell equipment failure. No power supply Check power supply. If power supply is OK, check display and display wiring, if OK, replace controller.

Walmart bayonne nj hours

As a first stage the compressor is discharging the refrigerant which is in a gas state into the condensing coil, since the refrigerant is on the compressor discharge high pressure side it will be heated and will flow through the condensing coil. Resulting with a refrigerant at liquid state with a temp drop as well. Smartphone application AirHome. Check if the size chosen for the complete room s load is enough or need bigger units. Unit capacity insufficient for load or room size. Follow us on social networks. Heat always flows from a warmer substance to a cooler one. No power supply Check power supply. COOL indicator off for 3s and blinks 20 times. The sensor has been broken or damaged. HEAT indicator off for 3s and blinks 13 times. Convection By transfer via a fluid or air.

If your Airwell air conditioner shows any strange symptoms, is not cooling, or is not working at all, the table below will be of great help. Find the symptom in the first column, analyze the possible causes and try the suggested solutions. These systems use the new refrigerant RA.

Poor cooling or heating performance. Thanks appreciate any feedback since this is the second time it went faulty in a less than two months installed. Restore power. Hot water tank Eleo. It is not working on cooling. The direction change is conducted by a component called 4 way valve heat pump. If power supply is OK, check display and display wiring, if OK, replace controller. Cold draughts are sometimes associated with air conditioning and indeed, this can be caused by incorrectly conceived systems. Check that no piping is in contact with each other or with other parts. Airwell Air Conditioner Error Codes. COOL indicator off for 3s and blinks 4 times. Possible reasons. HEAT indicator off for 3s and blinks 4 times.

2 thoughts on “Airwell air conditioner troubleshooting

  1. Excuse, I can help nothing. But it is assured, that you will find the correct decision. Do not despair.